The efficiency of heat exchange in vehicle systems is critically dependent on the material used, the technology employed and the quality systems followed. Pranav Vikas has leveraged its partnership with Sanden Corporation, Japan to offer a range of heat exchangers for variety of uses in the automobile industry.
The performance of a condensors is related to its ability to dissipate heat. Multi flow condensers are the latest in technology and innovation and able to make the air conditioning more effective by utilizing less space and power, thereby enhancing the overall performance.
 |
PRANAV 16/18mm thick MFC weigh approximately 50% less than 44mm serpentine model. |
 |
PRANAV MFC is suitable for both R12 and R134a refrigerants |
 |
PRANAV MFC design minimize air pressure drop and radiator heat load due to supper-thin profile. |
 |
PRANAV MFC can save up to 10% refrigerant usage of the circuit as compared to serpentine Condenser. |
 |
PRANAV MFC fitting channel is universally Applicable. |
| |
|
| |
|
| |
|
| |
|
| Parameter |
Requirements |
| Max. Core size |
: |
Height
: |
630 mm |
| |
|
Width : |
714 mm |
| Min. Core size |
: |
Height : |
200 mm |
| |
|
Width : |
253 mm |
| Depth |
: |
|
16,18, 28 mm |
| Tube Thickness |
: |
|
2.0 mm |
| Tube Pitch |
: |
|
10 mm, 9.8mm |
| Fin Pitch |
: |
|
1.3, 1.4 mm |
| Fin Thickness |
: |
|
0.08, 0.1, 0.115mm |
| Heat Capacity |
: |
|
8 to 13 kw |

| |
 |
Sumo |
 |