| Pranav Vikas R & D facility is jointly with Sanden Vikas and located at Sanden Vikas (A parent company of Vikas group).Sanden Vikas is a certified R&D centre by The Department of Scientific & Industrial Research (DSIR). SVL is a home to state of the art testing facilities, manned by a highly motivated and competent R & D team. SVL is constantly updating and improving its testing facilities to meet harsher testing standards required by its customers. The latest additions to the wide range of testing equipment include |
| |
- Noise, Vibration & Harshness Tester (NVH)
- High Function Durability Bench x 4
- Slugging Bench
|
| |
| The testing facilities are available to external organisations for hire. To find out more about the facilities, email us at testlab@sandenvikas.com |
| |
|
|
| Tests conducted |
|
- Cooling Capacity of Air-Conditioning System
- Heating capacity of Heater Unit Assembly
|
| Features |
|
- Temp: 15 ~ 50 °C
- % RH: 40 ~ 80
- Cooling capacity: 800 ~ 10000 Kcal/hr
- Evaporator Air Flow: 2.5 ~ 10 m/sec
|
- Capacity: 30 KW
- Temp: 35 ~ 100 °C
- Flow Rate: 0 ~ 1500 l/hr at 3 kg/cm2
|
- Capacity: 1000 ~ 1500 Kcal/r
- Temp: Ambient ~ 60 °C
|
- Comp Revolution: 600 ~ 3000 rpm
- Temp: Up to 120 °C
|
 |
|
|
|
Test conducted |
|
- Efficiency test of automotive air-conditioners (ODCD + Cool Down Test)
- Efficiency test of automotive engines
- Automotive environment simulation
|
Features |
|
- Temp Range: 10 °C above ambient ~ 60 °C
- Humidity: 60% at 45 °C & 80% at 35 °C
- Car Velocity Range: Up to 120 Kmph
- Solar Radiation condition: Up to 1200 watts/m2
- Driving Type: Front wheel & Rear wheel drive both (2 WD)
- Inner Dimensions of Environmental Chamber: 16m x 7m x 7m
- Blower Air Volume: 250,000 m3/hr
|
 |
|
| |
Electro Dynamic Vibration Shaker |
|
|
Tests conducted |
|
- Resonance search
- Vibration durability test
|
| Features |
|
- Operating Frequency: 5 ~ 2000 Hz
- Max. Displacement: 40 mm (p-p)
- Pay Load Capacity (on ILS): 200 kg
- Vibration controls: Sine, Random, Shock
|
 |
|
|
|
Tests conducted |
|
- Temperature Cycle Test
- High Temperature Holding Test
- Low Temperature Holding Test
- Temperature with Humidity Cycle
|
Features |
|
- Inner Dimension : 1m x 1m x 1m
- Temperature Range: -40 ~ 200 °C
- Temperature Accuracy: ±1 °C
- Relative Humidity: 20 ~ 97 %
- Temperature Change Rate: 1 °C/min (Empty Chamber)
|
 |
|
|
|
Tests conducted |
|
- Low Temperature Holding Test
- Thermal Shock Test
|
| Features |
|
- Inner Dimension: 1m x 1m x 1m
- Temperature Range: -40 °C to Ambient
- Temperature Accuracy: ±1 °C
|
 |
|
|
|
Tests conducted |
|
- High Temperature Holding Test
- Thermal Shock Test
|
Features |
|
- Inner Dimension: 1m x 1m x 1m
- Temperature Range: Ambient to 200 °C
- Temperature Accuracy: ±1 °C
|
 |
|
|
|
Tests conducted |
|
- High Temperature Holding Test
- Thermal Shock Test
|
Features |
|
- Inner Dimension: 1m x 1m x 1m
- Temperature Range: Ambient to 400 °C
- Temperature Accuracy: ±1 °C
|
 |
|
|
|
Tests conducted |
|
- Anti-corrosive test as per JIS Z2371
|
Features |
|
- Inner Dimension: 1m x 0.75m x 0.75m
- Temperature Range: Ambient ~ 50 °C
- Temperature Accuracy: ±1 °C
- Humidity: Up to 97% RH
- Fog collection: 0.5 ~ 2.0 mm/hr
|
 |
|
|
|
Tests conducted |
|
- Anti-corrosive test as per JIS H8681
|
Features |
|
- Inner Dimension: 1.2m x 0.75m x 0.9m
- Temperature Range: Ambient ~ 50 °C
- Temperature Accuracy: ±1 °C
- Humidity: Up to 97% RH
- Fog collection: 0.5 to 2.0 mm/hr
|
 |
|
|
|
Tests conducted |
|
- Tear Down Test
- Compressor Durability Test
|
| Features |
|
- Suction Pressure: 0.5 ± 0.2 to 3.7 ± 0.5 kg/cm2
- Discharge Pressure: 12 ± 0.5 to 29 ± 1.5 kg/cm2
- Compressor Rotation: 900 ~ 7000 rpm
|
 |
| |